Portable Capnoxi Capnography Gas Analyzer Display with SpO2 Monitor, SpO2 with Gas Analyzer

$2,350.00

In stock

FREE SHIPPING! Delivery in 3 Days

Capnoxi® Plus Monitoring the patient’s respiratory status during CPR
Assists in determining when to intubate or extubate
Verification of ET tube placement Alerts if accidental extubation occurs
Verification of Ventilation during transport
Specialized date export function, help analyzing sleep condition

Monitoring SpO2, pulse rate, ETCO2 and respiratory rate;
Update 255-hour historical data replay on PC through USB
Equip Spo2 and Respiratory Status Analysis Software, comprehensive data analysis
Suitable for clinical and emergency circumstance
SpO2, SpO2+CO2 selectable

Software Function
Professional Data Analysis Software for CO2 Monitoring
Connecting the palm monitor to PC through USB
Storing Unlimited patient’s data
Displaying ETCO2,SPO2 Trends Table
Controlling PC printer, outputting trend graph, trend table report
Recording and storage object’s respiration details in clinical

Main Unit’s Environment Requirement
Working: Temperature: 5℃~50℃;
Relative humidity: 0~95%;
Atmosphere Pressure: 70.0KPa~106.0KPa
Storage: Temperature: 0℃~70℃;
Relative humidity: 0~95%;
Atmosphere Pressure: 22.0KPa~120.0KPa

LED
Patient Alarm Indicator: Two colors: Yellow and Red
Sound Indicator
Loudspeaker: Play alarm voices
Interfaces

Power: 12VDC power socket x 1

USB: MINI USB socket x 1

Measurement Specification
Principle: NDIR single beam optics
Sampling Rate: 90mL/min, ±10mL/min
Initialization Time: Waveform displaying in 20 seconds

Range
CO2: 0~99 mmHg, 0~13 %
N2O: 0~100 VOL%
ISO: 0~6VOL%
ENF: 0~6VOL%
SEV: 0~8VOL%
RR: 2~150 bpm

Resolution
CO2: 0~40 mmHg ±2 mmHg
40 ~99 mmHg ±5% of reading

N2O: 0~100VOL%
±(2.0 vol% +5% of reading)

ISO: 0~6VOL%
±(0.3 vol% +2% of reading)

ENF: 0~6VOL%
±(0.3 vol% +2% of reading)

SEV: 0~8VOL%
±(0.3 vol% +2% of reading)

RR: ±1 bpm
Apnea Alarm Time: 20~60s

MAC value defines

1.0MAC: under an atmospheric pressure condition, give a person or animal skin stimulation, 50% of people or animals not body dynamic response or escape reflection occurs, the inhalation anesthetics in alveolar concentration.
To achieve 95% of people don’t respond to stimuli, the MAC value should reach to 1.3.
When MAC value is 0.4,most patients will wake up.

Anesthetic agents
Enflurane: 1.68
Isoflurane: 1.16
Sevoflurane: 1.71
Halothane: 0.75
N2O: 100%
Notice Desflurane’s MAC1.0 values differ with age
Age: 18-30 MAC 1.0 7.25%
Age: 31-65 MAC 1.0 6.0%

Power Specification
Input Voltage: 12V DC
Input Current: 2.0 A

Physical Specification
Main Unit
Weight: 0.65Kg
Dimension: 192mm x 106mm x 44mm

Hardware Specification
TFT Screen
Type: Colorful TFT LCD
Dimension: 5.0 inch

Battery
Quantity: 4
Model: Rechargeable lithium battery
Voltage: 3.7 V
Capacity: 2200mAh
Working time: 10 hours
Recharging time: 4 Hours

Standard:

CO2 Sample Line ……… 1Pcs
Nasal Tube ……………… 1Pcs
Water-trap Column ……… 1Pcs
Airway Adapter …………. 1Pcs
Power Adapter ………….. 1Pcs

Options:
SpO2 Cable (Adult hard shell sensor)
SpO2 Cable (Adult Soft shell sensor)
SpO2 Cable (Neonatal soft sensor)
SpO2 Cable (Pediatric hard shell sensor)
SpO2 Cable (Pediatric Soft shell sensor)
SpO2 Cable (Child finger clip)
SpO2 Cable (multi-site Y type)
SpO2 External Cable

Be the first to review “Portable Capnoxi Capnography Gas Analyzer Display with SpO2 Monitor, SpO2 with Gas Analyzer”

Your email address will not be published. Required fields are marked *

Reviews

There are no reviews yet.

Main Menu